51 - Parameters (cont'd)
40 = Datelock
Option not available
41 = Weekend Work
This parameter is used to enable or disable menu option 45.6 = TIMER CONTROL.Weekend Work. If
the parameter is set to 1, the engineer can assign a Pattern Day and the user can authorize Weekend Work-
ing. If the parameter is set to 0 (disabled — default setting), the message Option not available is displayed
on selecting menu option 45.6, Weekend Work.
42 = PIN Change
This parameter defines the expiry period of user codes allocated the PIN Change attribute (refer to option 42
= CODES). The PIN Change parameter is programmable within the range 0–12 months; the default is 0.
The user PIN must be changed before the assigned PIN Change month ends. On entering the expiring user
code a warning that the code is due to expire and a prompt to assign a new code is given to the user. The
period of this warning message is determined by the PIN Warning option (refer to menu option 42.2 =
CODES. PIN Warning).
The default value is 0 - this means that although codes have been allocated the expiry attribute, they do not
expire.
43 = Timer Access
Option not available.
44 = Early Open
This parameter determines the number of minutes before the Lockout OFF time that the system can be
manually unset when the Early Open option (refer to menu option 45 = TIMERS) is switched on. The
Early Open parameter is programmable within the range 0–240 minutes; the default is 0.
45 = High Security
This option allows RIO zones to be monitored for Constant Voltage Tampers. A constant voltage tamper is
activated if a zone detector is replaced by a constant voltage source, for example, battery. This feature can
either be enabled or disabled. Only RIO zones are affected by this feature.
The High Security feature is disabled by default in the RIO, so must be turned on by the panel for this feature
to be activated. The feature can be turned on from the panel via Parameter 45 (High Security). The default
value for this parameter is disabled. If enabled, all RIOs on the system are affected.
This feature is only supported by RIOs rev 1.2 and above and Smart PSUs rev 0.7 and above.