Data Storage (cont'd)

Using Storage Mode

On the Legacy panel, enter and leave Engineer mode, so the External RS232 module is recognised. Then re-
enter Engineer mode to use the storage mode facilities.
On the Legacy panel, enter menu 56.2.4=Communications.RS232.Copy/Overwrite.
To copy the programming data FROM the Legacy panel TO the Grade 3 panel, select 1=Copy Site. To
copy the programming data FROM the Grade 3 panel TO the Legacy panel, select 2=Overwrite Site.
Press 1 to start the copy procedure, or 2 to abort at any time. The copy procedure can also be aborted by
pressing esc on the Grade 3 panel; this exits Storage mode.
NOTE: The copy procedure is started as soon as the option is selected; neither panel requests confirmation
before proceeding.
During the copy procedure, the display on the affected keypad on the Grade 3 panel will show a message
indicating which data elements are being copied (Users, Parameters, etc).

Leaving Storage Mode

At any time, Storage mode can be exited by pressing esc on the Grade 3 panel. It is recommended that the
panels be separated before this is done, although doing so is not necessary. If the panels remain connected
while the Grade 3 panel is not in Storage mode, behaviour on line 2 of the Grade 3 panel and line 1 of the
Legacy panel cannot be guaranteed.