Honeywell Galaxy 3-48C Programming Manual page 94

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

53 - Program Outputs (cont'd)
2 = Output Mode
Each output function defaults to a specific, logical output mode. However, the output mode of each function
can be modified to meet special requirements: when reprogrammed, the new mode applies to all outputs
assigned to that function. The output modes are:
1 = Latch: the output remains active until a valid code is entered.
2 = Reflex: the output follows the activity of the triggering event, for example, the Set output follows the
setting and unsetting of the group.
3 = Pulse: the output remains active for the programmed pulse time 1-3000 seconds (50 mins).
Programming the Output Mode
Select the required mode using the A or B keys or by selecting the number 1 – 3. Once the required mode is
on selected, press the ent key to accept the programming. If assigning the Pulse output mode, enter the pulse
time (001 – 3000 seconds) and press the ent key.
3 = Output Polarity
The Output Polarity determines the normal operational state of the output. All outputs are referred to having
positive (0 = POS) or negative (1 = NEG) polarity. An output programmed as positive polarity is 12 V in the
normal condition and goes to 0 V when activated. A negative polarity output goes from the normal condition
of 0 V to 12 V in the active state. All outputs except SET (09) default to positive output mode.
NOTE: The Switch DC output is a positive polarity output, however, the normal condition is 0 V, going to
12 V when activated. The output mode is normally Pulse.
4 = Diag Recording
When this attribute is enabled, the selected output will be switched on during the diagnostic test (see Option
61.2.3=Diagnostics.Historical.Record).
This test can also be carried out remotely.
5 = Output Groups
NOTE: The Groups attribute is only available if groups have been enabled on the system (refer to option 63
= OPTIONS).
The Group attribute allows the output to be assigned to the groups on the system; an output can be assigned
to more than one group. All outputs default to all groups on the system.
On selecting the Output Groups attribute, the groups that the output is currently assigned to are displayed.
Press the relevant number keys to toggle the status of the group and press the ent key; if the group number is
displayed on the top line, then the group is assigned to the output; if a dash (–) appears in place of the group
number, the group has been removed from the output.
The output will activate if triggered by an event in any of the groups assigned to that output, unless output
group status has been programmed.
Galaxy 3 Series Programming Manual
88

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy 3-144Galaxy 3-144cGalaxy 3-520Galaxy 3-520c

Table of Contents