Honeywell Galaxy 3-48C Programming Manual page 120

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

56 - Communications (cont'd)
3 = Intelligent Test
This option stops the transmission of an automatic engineer test if an alarm signal has already been sent during
the autotest interval.
4 = Group Condition
NOTE: This option is only displayed if the groups have been enabled (refer to option 63 = OPTIONS).
The Group Condition determines the status that each group must satisfy before the Autotest is transmitted.
This can be used to prevent an Autotest from being signalled when groups are set on the system. On selecting
this option press the relevant number keys to toggle the status of the groups and press the ent key to accept
the programming. The available group status conditions are:
S = Set - group must be set to allow autotest transmission;
U = Unset - group must be unset to allow autotest transmission;
– = Set or unset - autotest transmission is independent of the group status.
08 Engineer Test
An engineer test can be sent to the alarm destination once the Account Number and the Telephone Number
1 have been entered, to ensure that the station is receiving transmissions sent from the Telecom module.
On selecting this option a warning message is displayed on the keypad, WARNING!!! ENT = SEND
MESSAGE. Press the ent key to send the engineer test.
The test attempts to transmit once for each selection of the option. If the test is not successfully transmitted,
the communicator does not attempt to resend. An unsuccessful transmission is not counted as a FAIL TO
COMMUNICATE.
NOTE: Activation of an engineer test will send a test signal via all Galaxy communication modules.
09 No. of Rings
This option determines the number of rings before the Telecom module answers an incoming call; the pro-
grammable range is 1 – 20, the default is 10.
10 Line Fail
The Telecom module continually monitors the telephone line that it is connected to. This option determines the
line monitoring conditions that result in a LINE FAIL event being reported and recorded in the log. The three
line monitoring capabilities are:
1 = Line Volts (default Enabled): A line fail occurs if the voltage on the telephone line falls below
three volts, or the line is cut.
2 = Dial Tone (default Disabled): A line fail occurs if the Telecom module cannot detect a dial tone
on the telephone line, when a dial attempt is made. In this case the Telecom module records the line
fail, but will continue the call attempt even if no dial tone is detected.
3 = Incoming Call (default Disabled): A line fail occurs if the Telecom module attempts to transmit
an alarm while there is an incoming call.
NOTE: Any combination of the above options may be enabled or disabled at any time.