Other (Parallel Converter Cable) - Omron FHV7H-C004-H19-MC Hardware Setup Manual

Vision sensor
Table of Contents

Advertisement

l [Output]
Object signals:
• No.20 to 23 pins: Connect the COMOUT1 and COMIN0 terminals when using these signals.
a) Internal specifications for NPN connection
Item
Internal circuit dia-
gram
b) Internal specifications for PNP connection
Item
Internal circuit dia-
gram
6-1-4

Other (Parallel Converter Cable)

When you change to connect the F series, FZ5 series, or FZ5-L series to FH series Sensor Controller,
you can convert by using the appropriate parallel converter cable of FH-VPX series under the usable
condition.
Corresponding model
FZ£ series
FZ£-L35£ series
F160-C10
F160
series
F160-C10CP
F160-C10CF
F210-C10
F210
series
F210-C10-ETN
F500
F500-C10
series
F250 series
F270 series
*1.
If the RESET signal becomes unavailable by conversion even though the signal has been used, but it caus-
es no problem, the conversion is possible by satisfying other required conditions.
FH Series Vision System Hardware Setup Manual (Z366-E1)
Con-
Applicable parallel
vertible
conversion cable
Yes
FH-VPX-FZ
Yes
FH-VPX-FZL
Yes
FH-VPX-F160
No
-
No
-
Yes
FH-VPX-F210
Yes
FH-VPX-F210
Yes
FH-VPX-F210
No
-
No
-
Specifications
COM IN
Load
+
Each output
terminal
COM OUT
Specifications
COM OUT
+
Each output
terminal
Load
COM IN
Required conditions
RESET is not used.
The same power supply is shared in
COMIN and COMOUT.
RESET is not used.
RESET is not used.
The same power supply is shared in
COMIN and COMOUT.
Do not use DI5 and DI6.
-
-
RESET is not used.
The same power supply is shared in
COMIN and COMOUT.
Do not use DI8 and DI9.
-
-
6 I/O Interface
6
*1
*1
*1
*1
6-19