Fh-2000/Fh-5000 Series - Omron FHV7H-C004-H19-MC Hardware Setup Manual

Vision sensor
Table of Contents

Advertisement

5 Setup and Wiring
5-5-2

FH-2000/FH-5000 Series

Precautions for Safe Use
• Ground
When a base is packed in a camera that will be connected to the Sensor Controller, make
sure to mount the camera using the base. Since the enclosure of the camera body is
connected to the internal circuits, mounting the camera without using the base allows the in-
ternal circuits to be directly connected to the ground, which may cause malfunction or failure.
• Connect the FH-2000/FH-5000 Series to FH-SC12/FH-SM12 (12 megapixels camera)
Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and a 12 megapixels camera like FH-SC12 or FH-SM12.
Mounting of Ferrite core
Mount the ferrite core attached to the camera cable to near the Sensor Controller.
*2. Each camera cables has polarity. Please ensure that the name plate side of the cable is connected
to the controller.
Camera cable mounting
Connect the cable with securing the connector length and the minimum bending radius to the Sensor
Controller.
Connector length
Minimum
bending radius
*2. Each camera cables has polarity. Please ensure that the name plate side of the cable is connected
to the controller.
5-24
FH Series Vision System Hardware Setup Manual (Z366-E1)
(Unit: mm)

Advertisement