2) Measuring distances

Press the [MSR] or [TRK] key on the
BMS or any other observation screens to
take a measurement.
When the Average count is set to 0, measurements are taken continuously
until [MSR]/[TRK] or [ESC] is pressed. Each time a measurement is taken,
the distance is updated.
For the Average count is set to 1–99, the averaged distance is displayed after
the last shot. The header "SD:" changes to "SDx" for this value.
If the signal level is insufficient for measurement, the signal icon will blink.
(See page 3-4)
・To change the Height of Target,
Temperature and Pressure, or
settings for measurement, press the
[HOT] key from any observation
screen. (See page 3-25)
・T-P correction, Sea level correction, C&R adjustment and Map
projection are included in Job settings. They can be defined when
creating a job. (See page 3-79)
・When the [MENU] key is pressed on the BMS or any other observation
screens, it stops the measurement and displays the MENU screen.
HA: 90°15'50"
VA:123°45'50"
SDx 1241.008 m
DSP1/4
:HT
5:Qedit
1
2:T-P
6:Qmode
3:Meas.
4:Level
3
3-18