HOT key

The [HOT] key is available from any
observation screen. It shows the screen
on the right.
3
Press the [ESC] key to return to the
previous screen.

1) Height of Target

You can define the height of target by
pressing the [HOT] and [1] keys.
2) Temperature & Pressure
Set the current temperature and pressure
using this command. Press the [HOT] and
[2] keys from the BMS or other
observation screens and type the ambient
temperature and pressure.

3) MSR/TRK Key Settings

Press the [HOT] and [3] keys to show the
[MSR] or [TRK] key settings.
(Same screen displayed by holding down
[MSR]/[TRK] for one second; See p.3-19)
Move the cursor by the up/down arrow
keys and use the right/left arrow keys to
change the setting.
Target = Prism/Sheet
Prism constant (Const) = –999~999mm
Mode = Prec/Normal
AVE
3-25

HOT

M
N
5
O
= 0(Continuous) ~ 99
:HT
5:Qedit
2:T-P
6:Qmode
3:Meas.
4:Level
Input HT
HT: 1.3560
Input T-P
Temp: 22 ° C
Press:1013 hPa
(ppm=0.4)
Measure mode
1:MSR Key
1
2:TRK Key
[1]/ [2]
>Target :Prism
Const
: 30 mm
Mode
:Prec
AVE
:1