8. Maintenance
Troubleshooting guide
Identification of problems during the job and possible solutions.
Problem
Quick couplers are not
coupling.
Equipment is moving
slowly, showing a lack of
power.
Lack of power on the
equipment.
- Only CAPABLE, QUALIFIED and AUTHORIZED personnel must carry out the
maintenance of the equipment.
122
PD / PCA / PCA PLUS - Rev. 01 - Jun/22
Probable cause
D i ff e r e n t b r a n d s o f q u i c k
couplers.
D i f f e r e n t t y p e s o f q u i c k
couplers.
Ruptured or smashed hydraulic
hoses.
Insufficient hydraulic pressure
on the control valve.
Low oil level.
Hydraulic cylinder with inner
leaks.
Hydraulic control valve with
inner leak.
Defect on the quick couplers.
Excessive load.
Inefficient or damaged tractor
hydraulic system.
Insufficient engine rotation.
Lack of pressure.
IMPORTANT
Solution
Use quick couplers from the
same brand.
Always use the same type of
quick couplers.
Unobstruct or change them.
Adjust the control valve through
the relief valve with the help of
a gauge. Normal pressure: 180
kg/cm
.
2
Fill up the reservoir to the level.
Te s t t h e e q u i p m e n t u s i n g
another hydraulic system. If
the problem persists, check/
replace the cylinder sealings
a n d a f t e r t h e p r o b l e m i s
solved check/adjust the tractor
hydraulic system.
Check the working conditions
of the hydraulic system or
replace the system for one with
a greater capacity.
Decrease the equipment load.
A d j u s t t h e c o n t r o l v a l v e
pressure to 180 kgf/cm².