Hyundai Robex 130 SMART Operator's Manual page 119

Hydraulic excavator
Table of Contents

Advertisement

Wait until the temperature is below 50 C
(122 F ) before removing the coolant system
pressure cap.
Failure to do so can cause personal injury
from heated coolant spray.
Drain the cooling system by opening the drain
valve on the radiator and removing the plug in
the bottom of the water inlet. A drain pan with a
capacity of 17.5 liters(4.6U.S.gallons) will be
adequate in most applications.
(2)
Flushing of cooling system
Fill the system with a mixture of sodium
carbonate and water(or a commercially
available equivalent).
Use 0.5kg(1.0pound) of sodium carbonate
for every 23 liters(6.0U.S. gallons) of water.
Do not install the radiator cap. The engine is
to be operated without the cap for this
process.
Operate the engine for 5 minutes with the
coolant temperature above 80 C(176 F) .
Shut the engine off, and drain the cooling
system.
Fill the cooling system with clean water.
Be sure to vent the engine and aftercooler
for complete filling.
Do not install the radiator cap or the new
coolant filter.
OK
START
ON
6-21
OFF
11076MI07
18036MI17
21076MA10
18036MI20

Advertisement