Local Terminal Configuration
Using a Local Terminal
2. Review the parameters as needed.
3. Press S or 0 to return to the probe's Main Menu.

Display Interface Summary

Use the following procedure to view the Display Interface Summary screen, as
shown in Figure 2-10 on page 36. The Interface Type will show the cable type
(such as V.11) if the cable type can be determined.
1. Press 4 from the Main Menu to access the Display Interface Summary
item.
The Display Interface Summary item displays the number and type of each
interface, the port type, and each port's IP address.
2. Press Enter to continue from the probe's Main Menu.
3. To exit the probe's Main Menu, press 7 to execute a warm start or press 8 to
execute a cold start. A cold start is required if you change the IP Address,
Default Gateway or Subnet Mask. For either menu choice, the probe exits
the Main Menu and restarts normal operations.
Display Interface Summary
Interface
------------
1.1/Ethernet
1.2/Serial
3.1/ATM
3.1/ATM-AL5
3.1/STS3C-STM1

Figure 2-10: Display Interface Summary

36
Port Type
----------
Telemetry
Not Applicable
Monitor-only
Monitor-only
Monitor-only
IP Address
-----------
15.6.72.216
0.0.0.0
Not Applicable
Not Applicable
Not Applicable