Agilent Technologies J3919A Installation & User Manual page 85

Oc-3 atmprobes
Table of Contents

Advertisement

NOTE
Verify that the Modem Init String is properly initialized for the attached modem
by referencing the modem's documentation. The probe's default modem
initialization string is configured to work with low-speed and medium-speed
Hayes compatible modems. The following modem settings are recommended for
low-speed to medium-speed modem connections:
Modem Flow Control:
Data Compression (if applicable):
Error Correction (if applicable):
Not all Hayes commands are the same for all Hayes-compatible modems. Refer
to your modem's documentation to determine the commands required for each of
the above settings and append these commands to the end of the default Modem
Init String.
Your modem's documentation discusses the features that are relevant to your
modem. If your modem does not support a feature (data compression, for
example), you do not need to turn it off in the Modem Init String.
Some modems require you to set register values explicitly, rather than sending
Hayes style commands. In this case, follow your modem's documentation to set
these registers.
If you are using a high-speed modem, you probably need to modify the default
modem initialization string. The following modem settings are recommended for
high-speed modem connections:
Modem Flow Control:
Carrier Detect:
Data Compression:
Error Correction:
After appending the appropriate commands to the modem initialization string,
warm start your probe.
Refer to your NetMetrix documentation for information on how to establish
communications with the probe over the SLIP link.
Off
Off
Off
Hardware Flow Control (RTS/CTS signaling)
Always On
Enabled
Enabled
Installation
Connecting the Probe
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

J3972a

Table of Contents

Save PDF