Cary 50
Spectrophotometer
Hardware Manual

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies Cary 50

  • Page 1 Cary 50 Spectrophotometer Hardware Manual...
  • Page 2 DFAR 252.227-7014 (June 1995), or as a “commercial item” as defined in FAR 2.101(a) or as “Restricted computer software” as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or Cary 50 Spectrophotometer Hardware Manual...
  • Page 3: Table Of Contents

    Color coding 9 CE compliance 10 2. Introduction Installation requirements 11 Documentation 11 Conventions Specifications 12 Environmental 13 Weights and dimensions 13 Computer power supply 13 Connections 3. Installation Cell holder 16 Alignment Other sample holders Cary 50 Spectrophotometer Hardware Manual...
  • Page 4 Windows XP service or driver failure 27 Access denied during installation 28 FCary service failed to start 29 No green light indicating that the Cary 50 is powered 30 Start button replaced with Connect button Hard disk power supply connection 32...
  • Page 5: Safety Practices And Hazards

    Information symbols 8 Color coding CE compliance 10 Your Agilent Cary 50 instrument and accessories have been carefully designed so that when used properly, you have an accurate, fast, flexible and safe analytical system. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
  • Page 6: Lamp Module

    IEC 60950. Modules, covers and panels The ONLY modules of the Cary 50 spectrophotometer that operators and other unauthorized personnel are permitted to access are the lamp module (on the underside of the instrument) and the sample compartment.
  • Page 7: Other Precautions

    Do not block any ventilation grilles present on the computer. Consult the manuals supplied with your computer, monitor and printer for their specific ventilation requirements. Use of the Cary 50 system and accessories may involve materials, solvents and solutions that are flammable, corrosive, toxic or otherwise hazardous.
  • Page 8: Information Symbols

    The following symbol may be used on warning labels attached to the instrument. When you see this symbol, refer to the relevant operation or service manual for the correct procedure referred to by that warning label. Cary 50 Spectrophotometer Hardware Manual...
  • Page 9: Color Coding

    The green indicator lamp on the front of the Cary 50 indicates the instrument is powered up (that is, the computer is switched on) and is in normal/standby condition. When the indicator lamp is flashing, this indicates the instrument is busy.
  • Page 10: Ce Compliance

    Safety Practices and Hazards CE compliance Agilent Cary 50 instruments have been designed to comply with the requirements of the Electromagnetic Compatibility (EMC) Directive and the Low Voltage (electrical safety) Directive (commonly referred to as the LVD) of the European Union. Agilent has confirmed that each product complies with the relevant directives by testing a prototype against the prescribed EN (European Norm) standards.
  • Page 11: Introduction

    Cary 50 spectrophotometer. You must prepare your laboratory according to these instructions before the Cary 50 can be installed. You should keep the pReinstallation manual for future reference. If you have misplaced your copy, you can obtain a free replacement from your local Agilent office.
  • Page 12: Conventions

    „Cary WinUV Software‟ with „UV Dissolution Software‟ or „UV Fiber Optic Dissolution Software‟ respectively. Specifications The instrument is suitable for indoor use only and is classified Pollution degree 2 and Installation Category II (EN 61010-1). Cary 50 Spectrophotometer Hardware Manual...
  • Page 13: Environmental

    Unpacked: 590 x 500 x 200 mm (23 x 20 x 8 in)  Computer power supply To ensure safe operation of the instrument, the switching power supply in the computer must comply with standard IEC 950 or equivalent. Cary 50 Spectrophotometer Hardware Manual...
  • Page 14: Connections

    Introduction The power requirements of the Cary 50 must be met by the computer power supply and the following capacity (in addition to what is required by the computer itself) is required:  +5 V DC <1 A +12 V DC <1.5 A ...
  • Page 15: Installation

    WARNING Heavy Weight Hazard The Cary 50 weighs over 20 kg (44 lb). To avoid injury to personnel or damage to equipment, always use two or more people when lifting or carrying the instrument. NEVER attempt to lift the instrument alone.
  • Page 16: Cell Holder

     This chapter describes how to install the sample holders used with the Cary 50, and how to uninstall the software and driver, should you ever need to. Instructions for installing/replacing the lamp module are included in the Maintenance chapter.
  • Page 17 Slide back the sample compartment lid (refer to Figure 2). Figure 2. Cary 50 showing the sample compartment lid (1) and front panel (2) Remove the sample compartment front panel (refer to Figure 2). If not already fitted, install the cell holder base in the sample...
  • Page 18: Alignment

    NOTE Other sample holders Other sample holders are available for use with the Cary 50, such as the Solid Sample Holder. Instructions for their use are included in the online Help provided with the Cary WinUV software. Refer to the Cary WinUV Software Manual (part number 8510162500) for details on using the online Help.
  • Page 19: Uninstalling The Cary Winuv Software

    Click the Windows Start button and choose Control Panel > System. On the Hardware tab, select Device Manager, and click the plus (‘+’) icon next to ‘Other’ devices. Right-click Cary 50 PCI Rev03 and then click Uninstall. Restart the computer. Cary 50 Spectrophotometer Hardware Manual...
  • Page 20 Installation This page is intentionally left blank. Cary 50 Spectrophotometer Hardware Manual...
  • Page 21: Maintenance

    4. Maintenance Cleaning Lamp module This chapter includes the Agilent Cary 50 spectrophotometer maintenance procedures that may be carried out by an operator. Any maintenance procedures not specifically mentioned in this chapter should be carried out only by Agilent-trained, Agilent-qualified or Agilent-authorized customer support representatives.
  • Page 22: Cleaning

    Cleaning Any spills in the sample compartment should be immediately wiped The exterior surfaces of the Cary 50 spectrophotometer should be kept clean. All cleaning should be done with a soft cloth. If necessary, this cloth can be dampened with water or a mild detergent. Do not use organic solvents or abrasive cleaning agents.
  • Page 23 (refer to Figure 3). As you remove the last screw, use one hand to support the lamp module. Figure 3. Underneath the Cary 50. The six screws to be removed are numbered Hold the lamp module out from the instrument and unplug the 3-pin connector from the Cary 50 (refer to Figure 4).
  • Page 24 Plug the 3-pin connector of the new lamp module into the instrument. Fit the lamp module in the base of the Cary 50, ensuring that the wiring is kept clear of the other parts of the instrument. Replace and tighten the six screws.
  • Page 25: Aligning The Source Mirror

    Remove the snap-out panel (refer to Figure 5) from the front of the instrument, using a flat-blade screwdriver to pry the panel open. This exposes the two source mirror adjustment screws. Do not remove the plastic bung next to the adjustment screws. NOTE Cary 50 Spectrophotometer Hardware Manual...
  • Page 26 Maintenance Figure 5. The snap-out panel (1) on the front of the Cary 50 On the Lamps tabbed page, monitor the aqua-colored ‘Current Signal’ bar as you use the supplied 2.5 millimeter hexagonal ball driver to slowly adjust one of the adjustment screws at the front of the instrument.
  • Page 27: Troubleshooting

    Windows XP service or driver failure Access denied during installation 28 FCary service failed to start No green light indicating that the Cary 50 is powered 30 Start button replaced with Connect button 30 Hard disk power supply connection 32...
  • Page 28: Access Denied During Installation

    Troubleshooting Double-click the failed event to determine the cause of the failed device. If it was the Cary 50 that failed to load, you will see the following description: ‘The FCary service failed to start due to the following error: The device is not ready.’...
  • Page 29: Fcary Service Failed To Start

    ‘The FCary service failed to start due to the following error: The system cannot find the file specified.’ Solution This indicates the Cary 50 device driver was not copied to the correct directory. It is possible you may not have access rights to the installation drive.
  • Page 30: No Green Light Indicating That The Cary 50 Is Powered

    Check the connection of the main instrument cable connecting the computer to the Cary 50. If the power indicator on the front of the Cary 50 is still not on, check the connection of the computer power supply connector to the Cary 50 card inside the computer.
  • Page 31 The ‘Start’ button will not become active or the ‘Connect’ button will not change to ‘Start’. Solution If the Cary software cannot locate the Cary 50 PCI card, the ‘Start’ button will not become active or the ‘Connect’ button will not change to ‘Start’. This is due to either: A memory address conflict with the Cary 50 PCI card and ...
  • Page 32: Hard Disk Power Supply Connection

    Connect the free end of the Y connector to the hard disk. Absorbance is 10 and fluctuates wildly during a scan Problem The Cary 50 is reporting 10 Abs and a scan like that shown in Figure 7 is displayed on the screen: Cary 50 Spectrophotometer Hardware Manual...
  • Page 33: Instrument Performance Testing

    Troubleshooting Figure 7. Wild absorbance fluctuation during a scan Solution The detector cable inside the Cary 50 sample compartment is not connected. Check that the 8-pin plug on the left side of the sample compartment is firmly plugged in. Instrument performance testing...
  • Page 34 When operating, the lamp module emits high-intensity light, which can damage eyes. To avoid eye damage, never operate the lamp module outside the instrument. The lamp module contains components operating at high voltages. To avoid electric shock, NEVER disassemble the lamp module. Cary 50 Spectrophotometer Hardware Manual...
  • Page 35: Wavelength Calibration

    Restart the computer. Agilent recommends that as part of your  standard operating procedure, you restart the computer attached to the Cary 50 monthly. Perform the Instrument Performance Test suite in ‘Validate’ to  ensure the instrument results meet specification.
  • Page 36 Troubleshooting This page is intentionally left blank. Cary 50 Spectrophotometer Hardware Manual...
  • Page 37: Spare Parts

    Spare Parts 6. Spare Parts These spare parts are available for use with your Agilent Cary 50 spectrophotometer. Always use Agilent-supplied spare parts, unless otherwise indicated. Part Part number Sample compartment lid („1‟ in Figure 8) 0910127200 Sample compartment front panel („2‟ in Figure 8) 0110642990 Lamp mirror adjustment cover („3‟...
  • Page 38 1) Sample compartment lid 2) Sample compartment front panel 3) Lamp mirror adjustment cover 4) Accessory cable port plate (at rear) Ordering details for other Cary 50 accessories are available on the Agilent Web site, www.agilent.com Cary 50 Spectrophotometer Hardware Manual...

Table of Contents