Cycling Power

A power outage or cycling power to the probe causes a warm start. The probe
does not have a power switch; therefore, cycling the power consists of
disconnecting and reconnecting the power cord.

Selecting the Warm Start Menu Item

Use the following procedure to warm start the probe using the probe's Main
Menu:
1. Connect a local terminal (or a PC emulating a terminal) to the probe. Refer
to Chapter 2 "Local Terminal Configuration" for information on connecting
a local terminal.
2. Press the CONFIG button once (on the back of the probe) to place the probe
into the configuration mode. Use a narrow, pointed object (like a pen) to
press the recessed CONFIG button. The probe then displays its Main Menu
on the terminal. Figure 5-1 shows the probe's Main Menu.
Main Menu - Revision
1. Modify/View configuration values ->
2. Modify/View security values ->
3. Modify/View interface values ->
4. Display interface summary
5. TFTP Download new firmware ->
6. XMODEM Download new firmware ->
7. Warm start and Exit
8. Cold start and Exit

Figure 5-1: The Probe's Main Menu

Probe Operation
Restarting the Probe