20. Remove spring (10).
21. Pull up on rod (11) and remove suction strainer (12).
22. Clean the strainer of all debris.
NOTE: Replace the strainer if damaged.
23. Replace the O-ring on the suction strainer cover.
24. Install the suction strainer with the rod and spring.
25. Replace the hydraulic system breather filter. See
"Replace the Hydraulic System Breather Filter" on
page 5-69.
26. Add hydraulic oil to the tank through the suction
strainer opening until the hydraulic oil level displays
full in the sight glass (13) on the hydraulic tank.
27. Install the suction strainer cover and fasteners.
28. Start the engine.
29. Run the engine for 10 minutes to circulate the
hydraulic oil in the hydraulic system.
30. Check the level in the tank and add hydraulic oil if
needed. See "Add Hydraulic Oil" on page 5-68.
31. Check for leaks.
SANY
Fig. 5-102
Fig. 5-103
Operation and Maintenance Manual — 0420
10
11
12
0002408
13
0000257
5-79