SANY SY265C LC Operation And Maintenance Manual page 123

Table of Contents

Advertisement

SY265C LC/SY265C LR Excavator OMM
1. Make sure that the key switch of both machines is OFF.
NOTICE!
Make sure that all jumper cables are securely
clamped to their connections.
Failure to follow this notice could damage the
machine or cause it to operate improperly.
2. Clamp one end of a jumper cable to the positive (+) red
terminal (1) of the drained battery.
3. Clamp the other end of the same jumper cable to the
positive (+) red terminal of the charged battery.
4. Clamp one end of a second jumper cable to the negative
(-) black terminal of the charged battery.
5. Clamp the other end of the second jumper cable to the negative (-) black terminal (2) of the discharged battery
or an unpainted area of the frame of the machine with the drained battery.
6. Start the engine with the charged battery and run it at medium rpm..
NOTICE!
Never crank the engine for more than 15 seconds. If the engine fails to start after 15 seconds,
stop and allow the starter motor to cool for at least 2 minutes before attempting another start.
If the engine fails to start after five attempts, contact a SANY dealer. Failure to follow this
notice could damage the machine or cause it to operate improperly.
7. Attempt to start the engine of the machine with the drained battery. Retry after 3 minutes if the engine will not
start.
NOTE: Contact a SANY dealer if the engine will not start after five attempts.
8. Perform steps 2 through 5 in reverse order to disconnect the jumper cables from the machine with the drained
battery and from the machine with the charged battery.
SANY
Fig. 4-38
Operation and Maintenance Manual — 0420
1
2
0000055
4-31