6. Remove the bottom access panel (3).
7. Place an appropriately sized container under the
radiator drain hose (4). For engine coolant capacity, see
"Capacities" on page 5-14.
8. Open the radiator drain valve (5).
9. Allow the engine coolant to completely drain into the
container.
10. When the engine cooling system is empty, close the
radiator drain valve.
NOTICE!
Dispose of drained engine coolant in
accordance with local environmental
regulations. Failure to do so could
damage the environment.
11. Add new engine coolant through the expansion tank
until the engine coolant level reaches the bottom of the
filler neck.
12. Install the expansion tank cap.
13. Start the engine and run it at low idle for several minutes to allow engine coolant to circulate.
14. Shut down the engine, then check the engine coolant level. See "Check the Engine Coolant Level" on page 5-
20.
15. Install the bottom access cover.
16. Close the engine cover.