5. Remove spring (3), rod (4), and strainer (5).
6. Clean the strainer of all debris.
NOTE: Replace the strainer if damaged.
7. Replace the O-ring on the suction strainer cover.
8. Install the suction strainer with the rod and spring.
9. Add hydraulic oil to the tank through the suction
strainer opening until the hydraulic oil level displays
full in the sight glass (6) on the hydraulic tank. See
"Check the Hydraulic Oil Level" on page 5-29.
10. Install the suction strainer cover and fasteners.
11. Start the engine.
12. Run the engine for 10 minutes to circulate hydraulic oil
in the hydraulic system.
13. Recheck the level in the tank and add hydraulic oil if
needed.
14. Check for leaks.