SY265C LC/SY265C LR Excavator OMM
4. Remove four fasteners (1) and remove the hydraulic
suction strainer cover (2).
5. Place the suction strainer cover back over the opening.
Do not secure at this time.
6. Remove the bottom cover (3) to access the hydraulic
tank drain plug.
7. Clean the area around the hydraulic tank drain plug (4).
8. Place an appropriately sized container under the drain
plug. See "Capacities" on page 5-14.
9. Remove the hydraulic tank drain plug and allow the
tank to drain.
NOTICE!
Dispose of used hydraulic oil properly. Failure
to do so could damage the environment.
10. Replace the O-ring on the hydraulic tank drain plug.
11. Install the hydraulic tank drain plug.
SANY
Fig. 5-97
Fig. 5-98