Action Rules
It is possible to configure either a delay time or a blocking time.
The blocking time defines the minimum time between two executed actions. The blocking time starts after the
execution of an action. During the defined time span no action is executed. When the blocking time is expired,
the data of the last received event during the blocking time is used for the action. Other events that occur during
the blocking time are discarded.
The delay time defines the time span between the reception of an event and the execution of the action. When
the delay time is expired the action is executed. All subsequently events that occur during the delay time are
discarded.