Syntax
:SENSe<n>:PATTern<m>:EQBoost:MODE?[<wsp><DEF|SET|INFO>]
Description
Query the ED equalizer boost mode.
Parameters
DEF: Query the default power-on value
SET: Query the current SET value
INFO: Provides a description of what the return values represent
By default, this command Query the current SET value.
Response
An integer indicating the ED equalizer boost mode.
Example
:SENSe3:PATTern2:EQBoost:MODE? -> 0
Command
:SENSe<n>:PATTern<m>:EQBoost:MODE
Syntax
:SENSe<n>:PATTern<m>:EQBoost:MODE<wsp><value|DEF>
Description
Set the ED equilizer boost mode.
Parameters
value: The desired boost mode
DEF: Restores the default value
Response
No response
Example
:SENSe3:PATTern2:EQBoost:MODE 0
:SENSe<n>:PATTern<m>:LOGic?
Command
Syntax
:SENSe<n>:PATTern<m>:LOGic?[<wsp><DEF|SET|INFO >]
Description
Query the ED pattern digital level logic.
Parameters
DEF: Query the default power-on value
SET: Query the current SET value
INFO: Provides a description of what the return values represent
By default, the command Query the current SET value.
Response
An integer indicating the current set digital level logic.
Example
:SENSe5:PATTern1:LOGic? INFO -> 0:LOW,NEGATIVE 1:HIGH,POSITIVE
Command
:SENSe<n>:PATTern<m>:LOGic
Syntax
:SENSe<n>:PATTern<m>:LOGic<wsp><0|NEGative|LOW|1|POSitive|HIGH|DEF>
Description
Set the ED pattern digital level logic.
Parameters
NEGative|LOW: Set to the positive logic
POSitive|HIGH: Set to the negative logic
DEF: Restores the default value
Response
No response
Example
:SENSe3:PATTern2:LOGic NEG
Command
:SENSe<n>:PATTern<m>:TYPE?
Syntax
:SENSe<n>:PATTern<m>:TYPE?<wsp><DEF|SET|LIST|ALL|INFO|LINKED>
Description
Query the ED pattern type
Parameters
DEF: Query the default power-on value
SET: Query the current SET value
LIST: Query the list of discrete options for configurable values
ALL: Query the values specified by DEF, SET, and LIST
INFO: Provides a description of what the return values represent
LINKED: Query the linked channels
By default, the command Query the current SET value.
Response
A single integer value, or a comma separated integer array. When ALL is requested,
the format is "<DEF>,<SET>,<LIST>".
Example
:SENSe3:PATTern2:TYPE? LIST -> 0,1,2,3,4,5,6