Slot commands
:POWer?
:POWer
:DATA<m>
:AMPlitude?
:AMPlitude
:CPOint?
:CPOint
:OUTPut?
:OUTPut
Configuration commands
:SENSe<n>
:CLOCk
:FREQuency
:ARBitrary?
:ARBitrary
:STanDard?
:STanDard
:MEASure<m>
:BATHtub
:STARt
:STOP
:MINErrors?
:MINErrors
:VOLTage?
:VOLTage
:EALarm
:MODE?
:MODE
:POINt?
:POINt
:VOLTage?
:VOLTage
:PHASe?
:PHASe
:STARt
:STOP
:ENABle?
:EDIagram
:HORIzontal?
:HORIzontal
:PatternLENgth?
:PatternLENgth
:STARt
:STOP
:VERTical?
:VERTical
:PATTern<m>
:EQBoost?
:EQBoost
:MODE?
:MODE
:LOGic?
:LOGic
Quantifi Photonics Ltd.
Description
- Query the power of the RF output clock
- Set the power for the RF output clock
- Query the current amplitude of the output signal
- Set the amplitude of the output signal
- Query the pattern cross point (%)
- Set the pattern cross point (%)
- Query the state of the pattern generator output
- Set the state of the pattern generator output
Description
- Query the current ED frequency arbitrary settings
- Set the current ED frequency to an arbitrary value within the valid
operating range
- Query the current ED frequency standard settings
- Set the current ED frequency to a standard value
- Start the bathtub measurement
- Stop a running bathtub measurement
- Query the threshold number of errors for the bathtub measurement
- Set the threshold number of errors for the bathtub measurement
- Query the bathtub voltage level
- Set the bathtub voltage level
- Query the mode of ED measurement
- Set the mode of ED measurement
- Query the ED point mode
- Set the ED point mode
- Query the ED point voltage level
- Set the ED point voltage level
- Query the ED point phase
- Set the ED point phase
- Starts the ED measurement
- Stops the ED measurement
- Query the enabled state of the ED
- Query the horizontal (x) resolution step size of the eye measurement
- Set the horizontal (x) resolution step size of the eye measurement
- Query the resolution of eye measurement pattern length (2^n bits)
- Set the resolution of eye measurement pattern length (2^n bits)
- Starts the eye scan measurement
- Stops the eye scan measurement
- Query the vertical (y) resolution step size of the eye measurement
- Set the vertical (y) resolution step size of the eye measurement
- Query the ED equalizer boost
- Set the ED equalizer boost
- Query the ED equalizer boost mode
- Set the ED equalizer boost mode
- Query the ED pattern digital level logic
- Set the ED pattern digital level logic
Version