Quantifi Photonics BERT 1005 Series User Manual page 69

Bit error rate tester
Table of Contents

Advertisement

Syntax
:SENSe<n>:MEASure<m>:BATHtub:MINErrors?[<wsp><MIN|MAX|DEF|SET|ALL|STE
P|UNIT|LINKED>]
Description
Query the minimum error threshold for the bathtub measurement
Parameters
MIN: Query the minimum threshold
MAX: Query the maximum threshold
DEF: Query the default threshold
SET: Query the set threshold
ALL: Query a comma separated string in the format [MIN, MAX, DEF, SET]
STEP: Query the minimum step between thresholds
UNIT: Returns the unit of the threshold
LINKED: Returns the linked channels
Response
A single integer value, or a comma separated integer array.
Example
:SENSe3:MEASure2:BATHtub:MINErrors? -> 10
:SENSe3:MEASure2:BATHtub:MINErrors? MIN -> 0
:SENSe3:MEASure2:BATHtub:MINErrors? MAX -> 65535
:SENSe3:MEASure2:BATHtub:MINErrors? DEF -> 10
:SENSe3:MEASure2:BATHtub:MINErrors? SET -> 10
:SENSe3:MEASure2:BATHtub:MINErrors? ALL -> 0, 65535, 10, 10
:SENSe3:MEASure2:BATHtub:MINErrors? UNIT -> bits
:SENSe3:MEASure2:BATHtub:MINErrors? LINKED -> 1
Command
:SENSe<n>:MEASure<m>:BATHtub:MINErrors
Syntax
:SENSe<n>:MEASure<m>:BATHtub:MINErrors<wsp><value|DEF>
Description
Set the current ED frequency to a standard value.
Parameters
value: The desired new value
DEF: Restores the default value
Response
No response
Example
:SENSe15:MEASure1:BATHtub:MINErrors 5
:SENSe15:MEASure1:BATHtub:MINErrors DEF
Command
:SENSe<n>:MEASure<m>:BATHtub:VOLTage?
:SENSe<m>:MEASure<n>:BATHtub:VOLTage?[<wsp><MIN|MAX|DEF|SET|ALL|STEP|
Syntax
UNIT|LINKED>]
Description
Query the bathtub voltage
Parameters
MIN: Query the minimum bathtub voltage
MAX: Query the maximum bathtub voltage
DEF: Query the default bathtub voltage
SET: Query the set bathtub voltage
ALL: Query a comma separated string in the format [MIN, MAX, DEF, SET]
STEP: Query the minimum step between bathtub voltages
UNIT: Query the unit of the bathtub voltage
LINKED: Query the linked channels
By default, the command Query the current SET value.
Response
A single integer value, or a comma separated integer array.
Example
:SENSe3:MEASure2:BATHtub:VOLTage? ->0.000000
:SENSe3:MEASure2:BATHtub:VOLTage? MIN ->-217.000000
:SENSe3:MEASure2:BATHtub:VOLTage? MAX ->217.000000
:SENSe3:MEASure2:BATHtub:VOLTage? DEF ->0.000000
:SENSe3:MEASure2:BATHtub:VOLTage? SET ->0.000000
:SENSe3:MEASure2:BATHtub:VOLTage? ALL ->-
217.000000,217.000000,0.000000,0.000000
:SENSe3:MEASure2:BATHtub:VOLTage? STEP ->7.000000
:SENSe3:MEASure2:BATHtub:VOLTage? UNIT ->mV
:SENSe3:MEASure2:BATHtub:VOLTage? LINKED -> 1
Command
:SENSe<n>:MEASure<m>:BATHtub:VOLTage
Quantifi Photonics Ltd.
Version
2.04
Bit Error Rate Tester | BERT 1005
69

Advertisement

Table of Contents
loading

Related Products for Quantifi Photonics BERT 1005 Series

Table of Contents