Charging Voltage Setpoints

Charging Voltage Setpoints

The XPLORE Charger charging process is designed to make the
battery or battery banks reach the following voltage setpoints.
Table 4 Charging Maximum Voltages
Absorption
Battery Type
Flooded
14.4
GEL
14.2
AGM
14.3
LiFePO
14.6
4  
14.4
Custom
(default,
changeable)
34
Float
Equalization
(Volts)
(Volts)
13.5
16.0
not
13.8
applicable
not
13.4
applicable
not
13.4
applicable
13.4
not
(default,
applicable
changeable)

Battery Qualification

The XPLORE Charger will perform a battery qualification on each
application of AC (or DC > 9 V), to determine if battery banks are
present and healthy.
To force a battery detection sequence,
1. Turn off AC and DC power sources.
(Volts)
2. Wait approximately 20 seconds or until all lights on the
charger or remote have gone out.
3. Turn on DC.
4. Turn on AC.
The charger will then perform a battery detection.

Temperature Considerations

The optional Battery Temperature Sensor (BTS) protects your
battery and improves charging accuracy. Attach the BTS to the
warmest battery.
If no BTS is connected, the charger defaults to 25 °C.