SAC 3600 Series Operator's Manual page 36

Maxi-mixer
Table of Contents

Advertisement

CONTROLS
522008
522008
522008
522009
522009
522009
522010
522011
522011
522012
522012
522013
522014
522015
522016
522016
522017
522017
522018
522018
522019
522019
OPERATION
REPLACEMENT PARTS
1
Warning: Front Hydro (1) System Pressure is Low.
Sensor OK! Check Hydro! High Speed Operation is
Disabled.
3
Warning: Front Hydro (1) Pressure Sensor has High
Voltage Output. High Speed Operation is Disabled.
Check Sensors and Wiring.
4
Warning: Front Hydro (1) Pressure Sensor has Low
Voltage Output. High Speed Operation is Disabled.
Check Sensors and Wiring.
1
Warning: Rear Hydro (2) System Pressure is Low.
Sensor OK! Check Hydro! High Speed Operation is
Disabled.
3
Warning: Rear Hydro (2) Pressure Sensor has High
Voltage Output. High Speed Operation is Disabled.
Check Sensors and Wiring.
4
Warning: Rear Hydro (2) Pressure Sensor has Low
Voltage Output. High Speed Operation is Disabled.
Check Sensors and Wiring.
14
Warning: Low Oil Level in Tank. Check for Leaks. Fill
Tank to Appropriate Level.
3
Warning: Aux 1 Pressure Sensor High Voltage. Check
sensors and wiring.
4
Warning: Aux 1 Pressure Sensor Low Voltage Output.
Check sensors and wiring.
3
Warning: Aux 2 Pressure Sensor High Voltage. Check
sensors and wiring.
4
Warning: Aux 2 Pressure Sensor Low Voltage Output.
Check sensors and wiring.
2
Warning: System Pressure is too High for High Speed
Operation. Unload Mixer until Pressure is Below
1500 PSI.
2
Warning: System Pressure Error. Augers Shifting back
to Low Speed Operation.
14
Warning: System Pressure is too High for High Speed
Operation. Shifting back to Low Speed.
3
Warning: Front Hydro 1 Coil Circuit is Open.
4
Warning: Front Hydro 1 Coil Circuit is Short Circuit to
Ground.
3
Warning: Rear Hydro 2 Coil Circuit is Open.
4
Warning: Rear Hydro 2 Coil Circuit is Short Circuit to
Ground.
3
High Speed Valve Coil is Open Circuit.
4
High Speed Valve Coil is Short Circuit to Ground.
3
Conveyor Motor Coil is Open Circuit.
4
Conveyor Motor Circuit is Short Circuit to Ground.
Check Hydro, oil level, and for
leaks. See Troubleshooting section
for details.
Check sensor and wiring. Replace
as needed.
Check sensor and wiring. Replace
as needed.
Check Hydro, oil level, and for
leaks. See Troubleshooting section
for details.
Check sensor and wiring. Replace
as needed.
Check sensor and wiring. Replace
as needed.
Check for leaks. Fill tank to
appropriate level.
Check sensor and wiring. Replace
as needed.
Check sensor and wiring. Replace
as needed.
Check sensor and wiring. Replace
as needed.
Check sensor and wiring. Replace
as needed.
Unload mixer until system
pressure is below 1500 PSI.
Check sensor and wiring. Replace
as needed.
Unload mixer until system
pressure is below 1500 PSI.
Check for loose wires and
connectors to front hydro coil.
Check for shorted wires and
connectors to front hydro coil.
Check for loose wires and
connectors to rear hydro coil.
Check for shorted wires and
connectors to rear hydro coil.
Check for loose or broken wires or
plugs to high speed valve coil.
Check for loose or broken wires or
plugs to high speed valve coil.
Check for loose or broken wires or
plugs to conveyor valve coil.
Check for loose or broken wires or
plugs to conveyor valve coil.
READ complete manual CAREFULLY