Refit & Check Window - Valor RetroFire RF24JDN Installation Manual

Direct vent gas
Table of Contents

Advertisement

Installation
Refi t and Check Window
1. Hook the glass window to the fi rebox then fastten
the four bolts pushing and turning them 90 degrees.
Verify that each bolt is properly hooked by feeling
with your fi ngers and ensuring the pin of the bolt
is hooked to the fi replace's fl ange.
x 4
2. Pull out the window by the sides and release it to
check that it opens slightly and returns confi rming
the good function of the spring-loaded mechanism.
3. Apply fi rm pressure around the window frame to
ensure the window is sealed tight against the fi re-
box.
4. If the Hot Glass Warning plate has been removed
from the front lower corner of the window, re-
install it by sliding it between the glass and the
frame as indicated.
Hot Glass Plate
32
Refit & Check Window
 WARNING
The window unit must be correctly
installed, fastened and sealed after
servicing or serious bodily injury and/or
damage to the appliance may result.
To ensure a safe operation:
• Double-check that the window frame is
correctly installed;
• Verify that the four bolts are hooked
properly to the window tabs then;
• Pull out the sides of the window and
release to ensure it returns to its position
and the springs are working;
• Press all around the window frame
against the firebox to ensure the window
is well sealed before operation.
 WARNING
Failure to install the window correctly can:
• Leak carbon monoxide;
• Affect the performance of the fireplace;
• Damage components;
• Cause overheating resulting in dangerous
conditions.
Damages caused by incorrect window
installation is not covered by the Valor
warranty.

Advertisement