Dimensions - Valor RetroFire RF24JDN Installation Manual

Direct vent gas
Table of Contents

Advertisement

Co-Linear with RA24CL
26-1/2"
23"
17-3/4"
4-1/2"
Top View
Gas Inlet
3/8" NPT Female
1-3/4"
26"
Minimum Cavity Dimensions
The diagram shows minimum dimensions required to install the RF24.
Cavities having a combination of all the minimum dimensions shown
possible, may prove to be difficult installations.
IMPORTANT! A free space of 3/4 inch (19 mm) is required in front of the
barrier screen to allow the window to move and relieve during a hard
start. The use of the optional fret sets this space with the fret bracket
installed.
However, when the fret is not used and the bottom cover is used
instead, this space immediately in front of the barrier screen must be
added to the minimum depth as a safety precaution. It is very
important to ensure that the area immediately in front of the barrier
screen is kept clear at all times even when not using a fret.
Centerline
Gas Inlet
3/8" NPT
Female
Control
4-3/16"
Valve
Location
1-3/8"
Optional Fret:
Mounting
Brackets
Optional Fan
Location
Control Valve
24-1/2"
RA24TB Fret (Black)
27"
RA24CV Fret (Vintage Iron)
Front Face of
Barrier Screen
8-1/4"
7-1/2"
Convection
Maintain
a 3/4" gap
in front
of barrier
screen
Barrier
Screen
Optional
Cast Fret
14"
14-5/8"
1-1/8"
15-3/4"
Minimum Insert Cavity

Dimensions

24-3/8"
8"
1225VFB Ventana Fret (Black)
10"
Optional Frets
14"
Levelling
- to screen
Feet
- to brackets
- w/fret
Height to Smoke Curtain
18"
14" without fret
15-3/4" with fret
27"
7-5/8"
20"
18"
11