Installation
Refi t and Check Window
1. Rest the window on the support
at the base of the fi rebox and
center it on the width.
2. While pressing the window
against the fi rebox, pull the
clamping bars levers forward
and rotate them inwards to se-
cure the top of the window.
3. Fit the two spring-loaded bolts
through the bottom of the win-
dow and tighten to secure the
window.
4. Pull the top of the window
forward and release to check
that it opens slightly and returns
confi rming the good function of
the spring-loaded mechanism.
5. Similarly, check the bottom of the window by pulling
it forward and releasing it.
6. Apply fi rm pressure around the window frame to
ensure the window is sealed tight against the fi re-
box.
7. If the Hot Glass Warning plate has been removed
from the front lower corner of the window, re-
install it by sliding it between the glass and the
frame as indicated.
32
Refit & Check Window
 WARNING
The window unit must be correctly
installed, fastened and sealed after
servicing or serious bodily injury and/or
damage to the appliance may result.
To ensure a safe operation:
• Double-check that the window frame is
correctly installed;
• Verify that the levers and spring-loaded
bolts are hooked properly to the window
tabs then;
• Pull out the top of the window and release
it to ensure the springs return it; repeat
with the bottom of the window;
• Ensure the window is sealed before
operation.
 WARNING
Failure to install the window correctly can:
• Leak carbon monoxide;
• Affect the performance of the fireplace;
• Damage components;
• Cause overheating resulting in dangerous
conditions.
Damages caused by incorrect window
installation is not covered by the Valor
warranty.