Installation; Window & Burner Removal - Valor RetroFire RF24JDN Installation Manual

Direct vent gas
Table of Contents

Advertisement

Installation

Prepare Appliance
The size of the existing fireplace cavity will affect the
method of installation. Smaller fireplaces, particularly
factory-built zero-clearance fireplaces will require the
RF24 firebox to be disassembled then reassembled
inside the fireplace. Plan your particular installation
accordingly.
Remove Window
1. Unhook barrier screen and window cover. The
screen is hooked to the window cover which in turn
is hooked to the fi replace at hte top and attached
with magnets at the bottom. Grabbing both the
screen and window cover, pull the bottom to detach
the magnets and unhook the top.
2. Remove window. Rotate the four fastening studs at
the bottom corners and sides 90 degrees to release
them. Unhook window and keep in a safe place.
x 4
Window & Burner Removal
3. Remove items packed inside fi rebox.
4. Strip fi rebox down by removing:
a. Log support (4 screws);
b. Burner module (10 screws);
c. Support legs (2 screws per leg) (required when
inserting into small fireplaces only).
Remove Burner
Module
Remove Log
(10 screws)
Support
(4 screws)
Remove Support
Legs (2 screws/leg)