Installation
Connect Venting Using RA24CA Co-Axial Vent Plate
Connect Venting Using RA24CA Co-Axial
with 3" x 5" liners from 590FVK2
IMPORTANT: This appliance's venting system is room sealed and therefore,
does not require room air to be used in the combustion process.
1. Stretch 3" and 5" liners from kit 590FVK2 individually to required
length. Insert the 3" liner inside the 5" liner and rough-in vent liners
into the existing chimney system from the roof. Be careful not to
tear or damage the liners in the process. Verify there is plenty of
liner at the bottom to facilitate the connection of the liners to the
vent slider so you will not need to stretch more later.
2. Trim 590FVK2's Terminal Adapter & Flashing as required to suit top
of chimney and fold a drip edge if desired.
3. Trim ends of liner if necessary and fasten to collars on the under-
side of the 590FVK2's terminal adapter using sheet metal screws
and gear clamps provided. Ensure liners are well secured and will
not fall down the chimney.
4. Apply a bead of sealant to top of chimney and seat 590FVK2's fl ash-
ing onto sealant.
5. Release the two screws retaining the vent slider plate to the front of
the fi rebox. Remove the plate from the fi rebox by sliding it towards
the back of the fi rebox.
6. Fit the two liners. Secure with hose clamps (included) and 2 tapping
screws per liner (inner liner fi rst, then outer).
7. Slide the fi rebox onto the vent slider in the cavity taking care not
to damage the liners. Make sure that the rear edge of the slider
is hooked over
the cleat on the
fi rebox. Secure the
vent slider to the
front of the fi rebox
with two screws
removed earlier.
See instructions
included with
590FVK2 kit for
full details.
 WARNING
Failure to position the parts in
accordance with these diagrams or
failure to use only parts specifically
approved with this appliance
may result in property damage or
personal injury.
24
Vent slider
cleat
Connect Venting—Co-Axial
5
7
Approved 4" x
6-5/8" vertical co-
axial termination
4
2
Terminal Adapter
and Flashing
supplied with
590FVK2
3
590FVK2
Flex Vent
Kit
1
6