Flueing Options - Rinnai Arriva Flue Installation Manual

Gas fireplaces
Hide thumbs Also See for Arriva:
Table of Contents

Advertisement

Flueing options

For lowest cost, optimal performance, ease of installation and servicing, Rinnai
recommend direct flued installations are considered before all other options.
Maximum flue
Maximum flue length
length and
Maximum number of bends
number of bends
For every 90° bend, the overall length must be reduced by 1 m. For example, if an installation has
three 90° bends, the maximum flue length can be 5.5 m. The elbow component of the adaption flue
kits is counted as a 90° bend.
Adaption flue kits
Arriva:
Evolve: use EVOKIT03
Direct and direct extended flueing
Direct through the wall flueing for walls up to 385 mm
thick. Flue can be extended if the wall thickness is
greater than 385 mm by using the ASPDFK flue kit and
additional lengths of ESPIPE900.
Sideways flueing
The sideways flue installation can run along the left or
right hand side of an internal wall behind the fire. When
considering the location of the fire, ensure the flue path is
free from obstructions such as noggins, wiring, joists etc.
Vertical in-wall flueing
A
B
The in-wall vertical flue is installed against an internal
wall within a false fireplace or other suitable cavity, and is
run vertically upwards towards a termination point.
C
Down and out flueing
This flue option allows for the adaption flue kit to face
downwards and for the flue to run vertically through a
hole in the floor, and then terminate horizontally outside,
flue termination must be 300 mm above ground level.
Through wall vertical flueing
For the small number of instances where the fire cannot
be directly flued or flued via an internal wall. In some
cases a large portion of the flue may be visible from the
outside.
use ASPKIT03
= 8.5 m
= three
Arriva
- Direct mushroom A flue (R2731), or
- Direct mushroom B flue (R2732), or
- Direct flue (ASPDFK)
Evolve
- Direct flue (ASPDFK)
- Adaption flue kit
- Flue pipe (ESPIPE900)
- Wall terminal (ESWTERM)
Vertical in-wall direct (A)
- Adaption flue kit
- Flue pipe (ESPIPE900)
- Roof cowl (ESROOFCOWL)
Vertical in-wall offset (B)
Above list + 45° bends (ESBEND)
Vertical in-wall horizontal (C)
- Adaption flue kit
- Flue pipe (ESPIPE900)
- 45° bends (ESBEND)
- Wall terminal (ESWTERM)
- Adaption flue kit
- Flue pipe (ESPIPE900)
- Wall plate (ESPLATE)
- 45° bends (ESBEND
- Wall terminal (ESWTERM)
- Direct flue (ASPDFK)
- 45° bends (ESBEND
- Flue pipe (ESPIPE900)
- Condensate trap (ESCONDK)
- Roof cowl (ESROOFCOWL)
Arriva/Evolve flue installation guide: 10726-I 09-21 | 5