Upgrading The Firmware Using Ftp; Step 1 - Determine The Ip Addresses - evertz HD9690 Series Instruction Manual

High definition graticule generator
Table of Contents

Advertisement

HD9690 Series HDTV Graticule Generator Manual
Prior to initiating the upgrade process:
Confirm the version of code currently installed on the unit by using the front panel display.
Download the new application code from the Evertz FTP site (www.evertz.com) Unzip the file into a
temporary working folder on your PC.

5.3.1. Upgrading the Firmware Using FTP

You will need the following equipment in order to update the Firmware:
PC with available communications port and ethernet network port. The communication speed is
1152600 baud, therefore a 486 PC or better with a 16550 UART based communications port is
recommended.
"Straight-thru" serial extension cable (DB9 female to DB9 male) or (DB25 female to DB9 male).
Appropriate ethernet cable as outlined in section 2.5.
Terminal program such as HyperTerminal
New firmware supplied by Evertz.
5.3.1.1.
Step 1 – Determine the IP Addresses
Before any FTP (file transfer protocol) upgrades can be initiated, the user must determine the IP address
of the HD9690unit. Both the PC/laptop and the unit must be on the same subnet for the FTP upgrade to
work properly.
1. Connect a 'straight through' serial cable to the UPGRADE/COM1 DB9 connector on the rear panel
2. Connect the 9 pin female connector on the end of the serial cable to the PCs' RS-232 communications
port
3. Start the terminal program.
4. Configure the port settings of the terminal program as follows:
5. Once the unit is powered-up, the HyperTerminal connection displays boot-up status information and
once completed, ends with the "Status Message" as shown below:
Initialization Completed - HD9690 Running
Page 5-4
115200
Baud
Parity
no
Data bits
8
Stop bits
2
Flow Control
None
Revision 1.5