3.5.3.3.

Controlling the Mask Size (Mask Centred, Aspect Ratio On)

Setup menu
Force centre
Mode menu
Aspect ratio
Or
Setup menu
Force centre
Mode menu
Aspect ratio
Mode menu
Centre
Size
When the mask is centred and aspect ratio MODE is On, the left and right shaft encoders are
used to adjust the overall size of the mask proportionately about its centre while maintaining
the selected aspect ratio. The size is adjusted about the centre of the raster.
3.5.3.4.

Controlling the Mask Size and Position (Mask not centred, Aspect Ratio Off)

Setup menu
Force centre
Mode menu
Aspect ratio
Mode menu
Centre
When the mask centering is Off and aspect ratio MODE is Off the H and V lines can be positioned
independently in one of four modes.
V track
The left shaft encoder is used to adjust the vertical position of the mask, i.e. move the mask up
or down and the right shaft encoder is used to adjust the height of the mask.
V no track The left shaft encoder is used to adjust the top of the mask and the right shaft encoder is used
to adjust the bottom of the mask.
H track
The left shaft encoder is used to adjust the horizontal position of the mask, i.e. move the mask
left or right and the right shaft encoder is used to adjust the width of the mask.
H no track The left shaft encoder is used to adjust the left side of the mask and the right shaft encoder is
used to adjust the right side of the mask.
3.5.3.5.

Controlling the Mask Size and Position (Mask not centred, Aspect Ratio On)

Setup menu
Force centre
Mode menu
Aspect ratio
Mode menu
Centre
When the mask centering is Off and aspect ratio mode is On the position and overall size of the mask can
be adjusted proportionately about the centre of the mask based upon the aspect ratio selected.
Position The left shaft encoder is used to adjust the vertical position of the mask, i.e. move the mask up
or down and the right shaft encoder is used to adjust the horizontal position of the mask, i.e.
move the mask left or right.
Size
The left shaft encoder is used to adjust the size of the mask with the bottom right corner fixed.
The right shaft encoder is used to adjust the size of the mask with the top left corner fixed. The
aspect ratio of the mask is maintained as the size is adjusted.
Page 3-18
Yes
1:1
4:3
14:9
16:9
No
1:1
4:3
14:9
16:9
H + V
no
off
off
No
1:1
4:3
14:9
16:9
Off
Revision 1.5
1.67:1
1.85:1
2.35:1
1.67:1
1.85:1
2.35:1
1.67:1
1.85:1
2.35:1