System connection
Readhead only
(no interface)
The ATOM readhead is available in several variants:
•
Cable variant with a 15 way D-type connector
•
Cable variant with interboard connector
•
FPC variant
None of these readhead variants has an integral calibration (CAL) button. Provision should be made
in the customers' electronics for momentarily connecting the CAL line to 0 V to initiate the calibration
routine, switch AGC on /off or restore factory defaults. See page
Calibration is an essential part of system set-up that optimises the incremental signals and phases the
reference mark. See page
34
for information on the calibration routine.
16
ATOM rotary encoder system
42
for pin-out information.
For cable variant with interboard connector
•
Ensure that the interboard connector is inserted into the connector on the customers' electronics
NOTE: Care should be taken to ensure correct orientation
•
Use a metal clamp around the cable ferrule to ground the readhead cable and ensure
continuity of the shields
•
Provide appropriate strain relief
•
Ensure suitable clamping to retain interboard connector to the mating connector
JST 12-way, single row 12SUR-32S.
Hirose
Interboard connector
JST mating connector: P-CN10-0051
14-way, dual row
(SM12B-SURS-TF).
DF23C-14DP-0.5 V
Hirose mating connector:
P-CN03-0024
(DF23-14DS-0.5 V)
1
13
2
14
Interboard connector