Readhead Mounting And Alignment; Methods; Shim Kit - Renishaw ATOM Installation Manual

Rotary encoder system
Hide thumbs Also See for ATOM:
Table of Contents

Advertisement

Readhead mounting and alignment

Methods

There is a range of tools available to assist with readhead installation depending upon the
system design; these are detailed below. For more details on designing the mounting bracket and
selecting the appropriate mounting tools, contact your local Renishaw representative.
Ensure that the disc, readhead optical window and mounting face are clean and free from
obstruction.
CAUTION: Do not saturate the readhead window with cleaning solvent as this may cause
contamination on the inside of the readhead window which cannot be cleaned.
AGC should be switched off before installing the readhead and, when reinstalling, factory defaults
should be restored.
NOTE: For FPC readheads, the FPC cable must be fitted prior to mounting the readhead. See
page
18
for more details.
IMPORTANT: Whichever method is used to mount the readhead, care should be taken to ensure
the scale surface is not damaged during this operation, particularly when metal-to-metal contact
is necessary.
28
ATOM rotary encoder system

Shim kit

Suitable for:
Applications where the rideheight of the readhead cannot be adjusted. The system should
be designed to achieve a nominal distance of 2.3 mm (±0.2 mm) from the readhead
mounting surface to the disc surface.
Mounting bracket
Disc
Shims of a known thickness are inserted between the mounting face of the readhead and the
bracket to give the correct rideheight.
Required parts:
Digital dial gauge (DTi) or similar
2 × M2 × 6 screws
ATOM readhead Shim kit (A-9401-0050) constisting of:
Part number
Thickness
Quantity
(µm)
in pack
A-9401-0041
20
10
A-9401-0042
40
10
A-9401-0043
60
10
A-9401-0044
80
10
A-9401-0045
100
20
A-9401-0046
200
20
A-9401-0047
300
10
Optional parts:
DTi adaptor (A-9401-0105)
Location pins
2.3 ±0.2 mm