System connection

Approved ESD precautions must be followed at
all times during readhead and interface electrical
connections. The readhead is connected to the
Ti/TD interface via a small, rugged connector to
allow for easy feed-through during installation.
Connecting the readhead
Remove the cover plate as shown
u
(2 x M2.5 hex head screws).
Taking care not to touch the pins, plug the
u
connector into the socket in the interface,
ensuring correct orientation as shown.
Refit the cover plate ensuring the cable ferrule is located in the recess on the inside and no wires are trapped under the cover plate.
u
TONiC RESM20 angle encoder system installation guide
Disconnecting the readhead
Remove the cover plate on the interface
u
(2 x M2.5 hex head screws).
Gently lever the connector PCB
u
(on the end of the cable) out of the socket.
Do not pull the cable to remove the
connector.
Place the connector in an anti-static bag.
u
u
Refit the cover plate.
14