Overview

Analytics

The Analytics button activates an interface that provides sensor data, plots, and other system
analytics for monitoring of the print process.

System Analytics

Print Chamber: The Print Chamber button displays readings for both the humidity and
pressure of the print chamber.
Interface Temperature: The Interface Temperature button displays the average and
maximum temperatures that the IR camera reads from the glass.
Interface & Resin IR Camera: The Interface and Resin IR Camera buttons display a
thermal image of the glass or resin tray respectively. Print layers can be viewed here in real
time as heat from the exothermic reaction of cured resin is transferred to the glass.
Interface Force: The Interface Force button displays the measured current (proportional to
force) being sent to the vertical linear drive to move the build arm.
UV Source: The UV Source button displays the temperature of LED light from the projector.
It also displays the readings from the internal light sensor.
Heating: The Heating button displays the measured temperature of the chamber and glass
interface.
Figure 4: Analytics screen