Tray Maintenance

Procedure
1. Open the printer door and remove the resin tray, if installed. Leave the door open.
2. Locate the linear drive grease kit within the accessory tools box.
3. Remove the blue cap from the grease syringe.
4. Using the gap between the linear drive (PMEC-10015-000) and cover, access the ball
screw shaft. Using the grease syringe, apply grease directly to the ball screw shaft.
5. Apply a 1ml bead of linear drive grease every 2 inches along the ball screw shaft.
6. Run the build platform calibration procedure. The calibration procedure causes the ball nut
to evenly spread grease on the ball screw shaft.
7. Repeat the calibration procedure an additional two times.
Tray Maintenance

Replacing Tray Sheets

Frequency
Replace as needed. Additionally, Stratasys recommends replacing tray sheets when changing
from a dark material to a light material or when changing from an industrial material to a
medical-grade material.
Figure 5: Linear drive grease kit