Bandit INTIMIDATOR 15XP/1390 Operating & Parts Manual page 42

Table of Contents

Advertisement

MODEL 15XP/1390
TROUBLE SHOOTING GUIDE cont.
PROBLEM
POSSIBLE CAUSE
Feedwheels Run
- Backup time set wrong.
In Reverse From
Normal
- Sticking reverse valve.
Type settings programmed
wrong.
NOTICE
Autofeeds with dump blocks can be unplugged and run manually. Autofeeds with dual output
block will need a jumper plug. This can be a good test to determine if you problem is hydraulic or electronic.
LOR Jumper Plug
Part No.: 900-2913-51
APPROXIMATE DIGITAL AUTOFEED SETTINGS
(FOR ALL AUTOFEED SYSTEMS - REFERENCE ONLY)
NOTICE
Refer to the Completion/Check Sheet, that is shipped with the machine for the correct engine
rpm. If needed, contact your local dealer or Bandit Industries.
Some Current Engine Types
GM 4.3 - 130 Hp
GM 5.7 - 165 Hp
CAT C3.4 / Perkins 854F - 74 Hp
CAT C4.4 / Perkins 1104D - 97 Hp
CAT C4.4 / Perkins 1104D - 114 Hp
CAT C3.4 / Perkins 854F - 112.5 Hp
Copyright 9/18
SOLUTION
- Reset backup time. Normal setting is 180 milliseconds
(139 for Models 12XPC/12XP/15XP/95/990) (IEC) or
.3 seconds (LOR)
- Check solenoid operation.
- Override cartridge manually by sticking a small
allen wrench in the end of the solenoid.
- Replace solenoid and/or cartridge.
- Reprogram or consult local dealer or Bandit Ind
IEC Jumper Plug
Part No.: 900-2914-09
Maximum
PPR
RPM
2600
2
2800
2
2200
N/A
2375
126
2375
126
2200
N/A
28
AUTOFEED OPTIONS
Off
On
Feed Reverse
RPM
RPM
2400
2150
180 / .3
2700
2400
180 / .3
2100
1750
180 / .3
2280
2030
180 / .3
2280
2030
180 / .3
2100
1750
180 / .3
Bandit
Time

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents