Bandit INTIMIDATOR 15XP/1390 Operating & Parts Manual page 159

Table of Contents

Advertisement

BANDIT CONTROLS
Main Page
1
2
2. Press 'Purge' button to trigger a reverse cycle on the radiator fan (if equipped).
3. Press this button to Navigate to the Mode page and select Radio or Tether operating mode.
(On Displays with software version 57193_D1 (19Jun2015) and later, the Display automatically returns to this
Main Engine page 60sec after last button press).
1
2
Press the Mode button to select between Manual, Radio, or Tether operating mode.
Lost Communication:
If Controller 1 (C1) loses communication with the Display, C1 will default to Radio mode.
If C1 loses comm with the Display AND the radio receiver, it will default to Tether Mode.
If C1 loses comm with display and receiver and tether, it will remain in Manual mode internally. Manual
Mode still allows the operator to at least start and idle and override valves manually.
245774458290 21Dec2016
3
4
5
3
4
5
Blinking
indicates that the
system has E-Stopped the engine.
- Hood Pin removed
- E-Stop depressed (if equipped)
Fuel Save Status: indicates that
Fuel Save mode is selected, and if
"Save" is blinking the system is
idled down to save fuel.
Fuel Level 0-100% (if equipped)
DEF Level 0-100% (applicable T4 engines)
Fault Status of the Radio and
Tether:
1=Good communication
0=Communication Fault
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents