Bandit INTIMIDATOR 15XP/1390 Operating & Parts Manual page 165

Table of Contents

Advertisement

BANDIT CONTROLS
Setup Page
1
2
1. Select down to the parameter you wish to adjust.
2. & 3. Increase or decrease the value of the selected parameter, or select through various options.
4. Go to more Settings (password protected).
5. Go back.
Fan Reverse Interval is optional on some machines. It is the time between fan reversing cycles to purge debris
from the radiator. The reverse cycle typically lasts between 20-30 seconds. The first number behind the 'Fan
Rev Interval' time setting is the engine fan state (0=neutral, 1=pulling forward, 14=reversing purge). The
second number behind the time setting is an error count of how many times the main controller (C1) has lost
communication with the fan control module since the last key cycle.
245774458290 21Dec2016
3
4
5
FuelSave Time: this is the amount of time the
machine will wait at "no load" until it idles down.
Fan Reverse Interval is optional on some machines.
It is the time between fan reversing cycles to purge
debris from the radiator.
The numbers behind the Fan Rev Interval is engine fan
state and communication error count.