Maintenance - Manitowoc Grove RT770E Service Maintenance Manual

Hide thumbs Also See for Grove RT770E:
Table of Contents

Advertisement

HOIST AND COUNTERWEIGHT
the flow from section two of pump number one to combine
with flow from section one.

MAINTENANCE

Warm-up Procedure
A warm-up procedure is recommended at each start-up and
is essential at ambient temperatures below 4°C (40°F).
The prime mover should be run at its lowest recommended
RPM with the hydraulic hoist control valve in neutral allowing
sufficient time to warm up the system. The hoist should then
be operated at low speeds, forward and reverse, several
times to prime all lines with warm hydraulic oil, and to
circulate gear lubricant through the planetary gear sets.
Failure to properly warm up the hoist, particularly under
low ambient temperature conditions, may result in
temporary brake slippage due to high back pressures
attempting to release the brake, which could result in
property damage, severe personal injury or death.
5-2
WARNING
Published 11/26/2014, Control # 447-05
Hoist Area Access
Platform must not be used for hauling passengers as
death or serious injury could occur.
No storage of components are allowed on the platform.
Only one person at a time is allowed on the platform.
Use the hoist access platform (1) (Figure 5-1) when working
in the hoist area.
Working Configuration
RT770E
WARNING
1
7451-2
FIGURE 5-1