Installing A Redundant Power; Installing An Ac Power Supply - Brocade Communications Systems NetIron CES 2000 Series Hardware Manual

Hide thumbs Also See for NetIron CES 2000 Series:
Table of Contents

Advertisement

Installing a Redundant Power Supply
The NetIron CES 2000 Series device ships with one alternating-current (AC) power supply or direct-current (DC)
power supply. All models have two power supply slots, enabling you to install a second power supply for
redundancy. If desired, you can install a second supply for redundancy.
CAUTION:
Changes or modifications made to this device that are not expressly approved by the party responsi-
ble for compliance could void the user's authority to operate the equipment.
If you need to install a redundant power supply, it may be easier to install it before mounting the device, although
the power supplies are "hot swappable" and can be installed or removed after the device is mounted and powered
on.
This section provides the following procedures:
Installing a redundant AC power supply – "Installing an AC Power Supply" on page 3-5
Installing a redundant DC power supply – "Installing an DC Power Supply" on page 3-7

Installing an AC Power Supply

WARNING: Before beginning the installation, see the precautions in "Power Precautions" on page 3-3.
Use the following procedures for AC power supplies in NetIron CES and CER 2000 Series devices.
To install an AC power supply, do the following:
1.
If necessary, remove the power supply locking screws located in the upper left and the bottom right of the
device (illustrated below).
March 2009
© 2009 Brocade Communications Systems, Inc.
Installation
3 - 5

Advertisement

Table of Contents
loading