Master reset function

RMP60 features a master reset function to assist users who have mistakenly changed the probe
settings into an unintended state.
The application of the master reset function using Trigger Logic™ will clear all current probe settings
and return the probe to default settings.
The default settings are as follows:
Radio switch-on
Radio switch-off
Trigger filter: Level 1
Hibernation mode on 30 s
Multiple probe mode off
The default settings may not be representative of the required probe settings. Further configuration of
the RMP60 may subsequently be necessary to achieve the required probe settings.
To reset the probe
1.
Insert the batteries or, if they have already been installed, remove them for 5 seconds and then
refit them.
2.
Following the LED check, immediately deflect the stylus and hold it deflected until eight red
flashes have been observed (if the battery power is low, each red flash will be followed by a blue
flash).
3.
Keep the stylus deflected until the "Switch-on method" setting (or first Trigger Logic menu) is
displayed, then release it.
4.
Deflect the stylus for 20 seconds. The status LEDs will flash yellow eight times. A confirmation for
master reset is required; if no action is taken, the probe will time out.
5.
To confirm that a master reset is required, release the stylus and then hold the stylus deflected
again until the eight yellow flash sequence has ended. This action clears all probe settings and
returns the probe to default settings. Following an LED check, the RMP60 returns to Trigger Logic
and displays "Switch-on method".
6.
Further configuration using Trigger Logic may be necessary to achieve the required probe
settings.