Renishaw RMP60 Installation Manual page 62

Radio machine probe
Hide thumbs Also See for RMP60:
Table of Contents

Advertisement

RMP60 installation guide
Symptom
RMP60 status LEDs do
not correspond to RMI-Q
or RMI-QE status LEDs.
7.4
RMI-Q or RMI-QE error
LED lit during probing
cycle.
RMI-Q or RMI-QE low
battery LED lit.
Reduced range.
Cause
Radio link failure – RMP60 out of
RMI-Q or RMI-QE range.
RMP60 has been enclosed/
shielded by metal.
RMP60 and RMI-Q or RMI-QE
are not partnered.
Probe not switched on or probe
timed out.
Probe out of range.
Dead batteries.
RMP60 and RMI-Q or RMI-QE
are not partnered.
Probe selection error.
0.5 second turn-on error.
Low batteries.
Local radio interference.
Action
Check position of RMI-Q or
RMI-QE, see operating envelope.
Review installation.
Partner RMP60 and RMI-Q or
RMI-QE.
Change setting. Review turn off
method.
Check position of RMI-Q or
RMI-QE, see operating envelope.
Change batteries.
Partner RMP60 with RMI-Q or
RMI-QE.
Verify that one radio probe is
working and is correctly selected
on the RMI-Q or RMI-QE.
Ensure that all radio probes are
'Q' or 'QE' marked probes, or
change the RMI-Q or RMI-QE
turn-on time to 1 second.
Change batteries soon.
Identify and remove.