Changing probe settings when partnered to an RMI-QE

Probe settings can be changed using Trigger Logic. Insert the batteries or, if they have already been
installed, remove them for 5 seconds and then refit them.
Following the LED check, immediately deflect the stylus and hold it deflected until eight red flashes
have been observed (if the battery power is low, each red flash will be followed by a blue flash).
Keep the stylus deflected until the "Switch-on method" setting is displayed, then release it.
Key to the symbols
LED short flash
LED long flash
Deflect the stylus for less than 4 seconds
to move to the next menu option.
Deflect the stylus for more than
4 seconds to move to the next menu.
To exit, leave the stylus untouched for
more than 120 seconds.
To exit, leave the stylus untouched for
more than 20 seconds.
Radio on
(omitted if "multiple probe mode" was selected)
Switch-off method (timeout options not applicable in "Shank mode")
Radio off or Spin
off or Shank off
Deflect the stylus and hold it deflected until after the battery
status has been displayed at the end of the review sequence.
Battery good
Switch-on method
Shank on
Short timeout
Medium timeout
12 s
33 s
1
2
> 5 s
3
LED Check
Battery status
Battery low
or
Spin on
Long timeout
134 s