RMP60 switch-on method
Switch-on options are configurable
Radio on
Radio switch on is commanded by
machine input.
Spin on
Spin at 500 r/min for 1 second
minimum.
Shank switch on
NOTES:
In "radio on mode", the switch-on time is user selectable "fast" or "standard" when using RMI-Q or
RMI-QE (selection is made in the relevant interface).
For more information on the user selectable switch-on time when operating with RMI-Q or RMI-QE,
refer to the RMI-Q radio machine interface installation guide (Renishaw part no. H-5687-8504) or the
RMI-QE radio machine interface installation guide (Renishaw part no. H-6551-8520).
In "radio on mode", the switch-on time assumes a good radio communication link. In a poor radio
frequency (RF) environment the switch-on time may increase.
In "spin on mode", the 1 second starts from the moment the spindle reaches 500 r/min.
The RMP60 must be on for a minimum of 1 second before being switched off.
Timeout off is not applicable in level start mode, refer to the RMI-Q radio machine interface installation
guide (Renishaw part no. H-5687-8504) or the RMI-QE radio machine interface installation guide
(Renishaw part no. H-6551-8520).
RMP60 switch-off method
Switch-off options are configurable
Radio off
Radio switch off is commanded by
machine input. A timer automatically
switches the probe off 90 minutes
after the last trigger or reseat if it is
not turned off by machine input.
Timer off (timeout)
Timeout will occur 12, 33 or 134
seconds (user configurable) after the
last probe trigger or reseat.
Spin off
Spin at 500 r/min for 1 second
minimum. A timer automatically
switches the probe off 90 minutes
after the last trigger if it is not spun.
Timer off (timeout)
Timeout will occur 12, 33 or 134
seconds (user configurable) after the
last probe trigger or reseat.
Shank switch off
Probe ready time
1 second maximum
(see notes below).
1 second maximum
(see notes below).
1 second maximum
2.5