RMP60 installation guide
Symptom
The machine stops
unexpectedly during a
probing cycle.
7.2
The probe crashes.
Cause
Radio link failure/RMP60 out of
range.
RMI-Q or RMI-QE receiver/
machine fault.
Dead batteries.
Excessive machine vibration
causing false probe trigger.
Probe unable to find target
surface.
Stylus not given sufficient time to
settle from a rapid deceleration.
False probe trigger.
Selection error for RMI-Q or
RMI-QE.
Workpiece obstructing probe path.
Probe length offset missing.
In cases where there is more than
one probe on a machine, incorrect
probe activated.
Action
Check interface/receiver and
remove obstruction.
Refer to receiver/machine user's
guide.
Change batteries.
Change trigger filter setting.
Check that part is correctly
positioned and that stylus has not
broken.
Add a short dwell before the
probing move (length of dwell will
depend on stylus length and rate
of deceleration).
Change trigger filter setting.
Review interface error indication
and correct.
Review probing software.
Review probing software.
Review interface wiring or part
program.