Changing the probe settings

Insert the batteries or, if they have already been
installed, remove them for five seconds and then
refit them.
Following the LED check, immediately deflect the
stylus and hold it deflected until five red flashes
4.4
have been observed (if the battery power is low,
each red flash will be followed by a blue flash).
Keep the stylus deflected until the "Switch-on
method" setting is displayed, then release it. The
probe is now in configuration mode and Trigger
Logic is activated.
CAUTION: Do not remove the batteries whilst
in configuration mode. To exit, leave the stylus
untouched for more than 20 seconds.
Key to the symbols
LED short flash
LED long flash
Deflect the stylus for less than 4 seconds
to move to the next menu option.
Deflect the stylus for more than
4 seconds to move to the next menu.
To exit, leave the stylus untouched for
more than 20 seconds.
Switch-on method
Radio on
(omitted if "Multiple probe
mode" was selected)
Switch-off method
Radio off or
Short
Spin off
timeout
12 s
Trigger filter
off 0 ms
3
1
Battery good
Spin on
Medium
Long
timeout
timeout
33 s
134 s
Enhanced trigger filter
Trigger filter
on 10 ms
2
> 5 s
LED check
Battery status
Battery low
or