SECTION 2
LIMIT A TIO NS
2.9 POWERPLANT INSTRUMENT MARKINGS
Tachometer
(a)
Green Arc (Normal Operating Range)
Red Line (Maximum)
Oil Temperature
(b)
Green Band (Normal Operating Range)
Red Line (Maximum)
Oil Pressure
(c)
Green Band (Normal Operating Range)
Yellow Band (Caution Range) (Idle)
Yellow Band (Ground Warm-Up)
Red Line (Minimum)
Red Line (Maximum)
2.11 SYSTEMS LIMITATIONS
(a)
Alternator
Emergency Battery
(b)
Minimum
2.13 WEIGHT LIMITS
Maximum Ramp (lbs.)
(a)
Maximum Weight (lbs.)
(b )
Maximum Baggage (lbs.)
(c)
REPORT: VB-2749
2 -4
PA-28-181, ARCHER ill
500 lo 2700 RPM
2700RPM
°
75
to 245
55 PSI to 95 PSI
25 PSI to 55 PSI
95 PSI to 115 PSI
70 AMPS
23.3 VOLTS
Normal
2558
2550
200
ISSUED: December 22, 2017
REVISED: July 15, 2020
•
°
F
245
°
F
25 PSI
l 15 PSI
•
Utility
2138
2130
0
•